# Transport 1.6 End of Trip Facilities - Non-Residential

# Applies to

All non-residential development

# Objective

To minimise car dependency and to ensure that the built environment is designed to promote the use of public transport, walking and cycling.

# Summary

Points are awarded when a proposal achieves the bicycle parking credits for non-residential developments and provide accessible showers (1 per 10 bicycles spaces or part thereof), changing facilities adjacent to showers and one secure locker per bicycle space in the changing facilities.

Examples:

  • A project with 10 bicycle parking spaces would require 1 accessible shower and 10 lockers
  • A project with 11 bicycle parking spaces would require 2 accessible showers and 11 lockers
  • A project with 15 bicycle parking spaces would require 2 accessible shower and 15 lockers

# Documentation & evidence required

Include on the floor plans:

  • Accessible showers that are within 100 metres  of the building entry at a rate of 1 per 10 bicycle spaces which are located within the change facilities and are notated to dispense hot and cold water and have efficient fixtures as compliant with the water efficiency section of this tool.
  • Change facilities adjacent to showers which include a wash basin with efficient fixtures as compliant with the water efficiency section of this tool, a bench, and are notated to include a hook, mirror and general power outlet.
  • 1 secure locker per bicycle space in the changing facilities with a minimum dimensions of 300mm(w) x 450mm(d) x 900mm(h)